Bojin SYSTEM 2000 orthopedic power tool BJ2104 cranial drill attachment—multifunctional
BOJIN SYSTEM 2000 BJ2104 Cranial Drill Attachment est developatus ad perforationem cranii et forationem cranii regulatam, utens intervallo operationis 0–1100 rpm ad praebendum motum rotationalem mensuratum durante proceduris ad accessum cranii; eius configuratio specialis perforatoris, connexio rapida cup-link et positio 360° permittunt aequipe chirurgico instrumentum parare secundum postulationes procedurarum neurochirurgicarum.
- Panoramica
- Producta Recommandata


Functionis specialis perforationis cranii pro SYSTEMA 2000
BJ2104 est accessorium specialis perforatoris cranii pro multifunctionali platforma chirurgica BOJIN SYSTEMA 2000. Praecipua eius functio est perforatio cranii, quae systemati optionem specialis praebet pro proceduris neurochirurgicis quae aperturam in cranio parare postulant.
Quia BJ2104 est accessorium, non autem manubrium integrum et separatim operans, potest unitatem potentiae SYSTEMATIS 2000 cum aliis functionibus chirurgicis communicare. Hoc permittit hospitalibus platformam secundum proceduram configurare, non autem systema motoris separatum pro singulis officiis uti.
0–1100 rpm pro Perforatione Mensurata
BJ2104 specificatur cum intervallo velocitatis rotationis 0–1100 rpm. Hoc intervallum operationis profilum perforationis regulatum praebet pro proceduris ubi motus instrumenti constans magis optatur quam frustulatio ad altam velocitatem.
The relatively moderate speed also helps distinguish this model from the SYSTEM 2000 cranial bur attachment, which is designed for much faster rotary operation. The two attachments therefore have different roles within the same product family.
Cranial Perforator Included
The BJ2104 configuration includes a cranial perforator. This gives the attachment a clearly defined role in cranial access procedures and avoids the need to source the primary perforation accessory separately.
The perforator should be used only with compatible equipment and according to the applicable instructions for use and surgical technique.
Designed for Cranial Access Procedures
The main purpose of the BJ2104 is to support cranial drilling and perforation work. A dedicated drilling attachment can simplify equipment preparation when the surgical team already knows that a cranial-access function will be required.
Its focused configuration also helps distinguish the instrument from general orthopedic drilling attachments that are intended for other types of bone preparation.
Parametri Producti
Voltage Laborans |
14.4V |
||||||
Bateria NiMH |
14,4V, 1800mA |
||||||
Sterilizabilis in autoclave |
134 °C, 5 min |
||||||
Adiunctum serrae sagittalis |
Oscillationes (osc/min): 15000 Rumor (db) ≤75 |
||||||
Accessoriolum perforatorium velox |
Velocitas (r.p.m): 0–1100; Torque maximum: 2.5 Nm; Rumor (dB) ≤75 |
||||||
Accessoriolum perforatorium parvum AO |
Velocitas (r.p.m): 0–1100; Torque maximum: 2.5 Nm; Rumor (dB) ≤75 |
||||||
Accessoriolum perforatorium canulatum |
Velocitas (r.p.m): 0–600; Torque (Nm): 4.5 Nm; Rumor (dB) ≤75 |
||||||
Accessoriolum rasile acetabuli |
Velocitas (r.p.m): 0–270; Torque maximum (Nm): 10 Nm; Rumor (dB) ≤75 |
||||||
Accessoriolum perforatorium cranialis |
Velocitas (r.p.m): 0–1100; Torque maximum: 2.5 Nm; Rumor (dB) ≤75 |
||||||
Accessoriolum terebrans cranialis |
Potentia exsors ≥90 W; Velocitas (r.p.m): 0–17000; Rumor (dB) ≤75 |
||||||
Adiunctum segonis sterni |
Potestas ≥90w Oscillationes (osc/min): 0-15000 Rumor (db) ≤75 |
||||||
Adiunctum segonis reciprocantis |
Oscillationes (osc/min): 0-15000 Rumor (db) ≤75 |
||||||
Adiunctum limitatoris torque (1.5NM) |
Oscillationes (osc/min): 0-15000 Rumor (db) ≤75 |
||||||
Adiunctum limitatoris torque (4NM) |
Torque: 1.5Nm Velocitas (r.p.m): 0-300 Rumor (db) ≤75 |
||||||
Adiunctum segonis oscillantis (typus TPLO) |
Torque: 4Nm Velocitas (r.p.m): 0-300 Rumor (db) ≤75 |
||||||
Accessio pernisi et fili |
Velocitas (r.p.m): 0–1100; Torque maximum: 3 Nm; Rumor (dB) ≤75 |
||||||

Quick Cup-Link Connection
The SYSTEM 2000 platform uses a quick cup-link attachment mechanism. This allows the compatible handpiece to be fitted with the BJ2104 as part of the modular setup.
For operating rooms that use several surgical attachments, a quick connection can make equipment changes more straightforward during preparation.
360° Rotating Attachment Position
The attachment interface supports 360° rotation, giving the operator additional freedom when setting the orientation of the cranial drill.
This can be useful when preparing the handpiece according to the surgical approach or when the working angle needs to be adjusted before the procedure begins.
A Clear Difference From the Cranial Bur
The SYSTEM 2000 offers both a cranial drill and a cranial bur attachment, but their operating characteristics are different.
BJ2104 est enumeratus ad 0–1100 rpm et suppeditatur cum perforatore craniali, ergo est optio specificior pro foraminibus et perforationibus. Per comparationem, burr cranialis BJ2105 est enumeratus ad usque 17 000 rpm et destinatur ad molendinam rotatoriam alti velocitatis.
Haec distinctio facit ut hospitalia et distributores facilius eligant aptum adfectum secundum proceduram propositam.
Proprietas producti


BJ2101
BJ90221.0A*1
BJ90141.0A*1
BJ70240.8B*1

BJ2102

BJ2103

BJ2104

BJ2105

BJ2106

BJ2107

BJ2109

BJ2112


Option 2: We can provide your engineers with online training and free repair parts so that you can handle it locally and be more efficient.







We look forward to the opportunity to work with you!
Semper exemplum ante productionem massam;
Semper inspectio finalis ante shipment;
3. quid a nobis emere potes?
Ferramenta Chirurgica Motu Acta et Accessoria, Radiographia, instrumenta motu acta orthopaedica, instrumenta orthopaedica, medica
4. Quid servitia praebere possumus?
Admissa Condicio Portandi: FOB,CFR,CIF;
Accepta Moneta Solutionis: USD, EUR, JPY, CAD, AUD, HKD, GBP, CNY, CHF;
Genera Pecuniae Accepta: T/T, MoneyGram, Western Union, Nummus;
Linguae Loquentes:Anglica,Sinensis,Russica